Documentation / devicetree / bindings / arm / bcm / brcm,bcm63138.txt


Based on kernel version 6.8. Page generated on 2024-03-11 21:26 EST.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85
Broadcom BCM63138 DSL System-on-a-Chip device tree bindings
-----------------------------------------------------------

Boards compatible with the BCM63138 DSL System-on-a-Chip should have the
following properties:

Required root node property:

compatible: should be "brcm,bcm63138"

An optional Boot lookup table Device Tree node is required for secondary CPU
initialization as well as a 'resets' phandle to the correct PMB controller as
defined in reset/brcm,bcm63138-pmb.txt for this secondary CPU, and an
'enable-method' property.

Required properties for the Boot lookup table node:
- compatible: should be "brcm,bcm63138-bootlut"
- reg: register base address and length for the Boot Lookup table

Optional properties for the primary CPU node:
- enable-method: should be "brcm,bcm63138"

Optional properties for the secondary CPU node:
- enable-method: should be "brcm,bcm63138"
- resets: phandle to the relevant PMB controller, one integer indicating the internal
  bus number, and a second integer indicating the address of the CPU in the PMB
  internal bus number.

Example:

	cpus {
		cpu@0 {
			compatible = "arm,cortex-a9";
			reg = <0>;
			...
			enable-method = "brcm,bcm63138";
		};

		cpu@1 {
			compatible = "arm,cortex-a9";
			reg = <1>;
			...
			enable-method = "brcm,bcm63138";
			resets = <&pmb0 4 1>;
		};
	};

	bootlut: bootlut@8000 {
		compatible = "brcm,bcm63138-bootlut";
		reg = <0x8000 0x50>;
	};

=======
reboot
------
Two nodes are required for software reboot: a timer node and a syscon-reboot node.

Timer node:

- compatible: Must be "brcm,bcm6328-timer", "syscon"
- reg: Register base address and length

Syscon reboot node:

See Documentation/devicetree/bindings/power/reset/syscon-reboot.yaml for the
detailed list of properties, the two values defined below are specific to the
BCM6328-style timer:

- offset: Should be 0x34 to denote the offset of the TIMER_WD_TIMER_RESET register
  from the beginning of the TIMER block
- mask: Should be 1 for the SoftRst bit.

Example:

	timer: timer@80 {
		compatible = "brcm,bcm6328-timer", "syscon";
		reg = <0x80 0x3c>;
	};

	reboot {
		compatible = "syscon-reboot";
		regmap = <&timer>;
		offset = <0x34>;
		mask = <0x1>;
	};