Based on kernel version 6.3.13
. Page generated on 2023-08-29 08:35 EST
.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 | Ralink Watchdog Timers Required properties: - compatible: must be "ralink,rt2880-wdt" - reg: physical base address of the controller and length of the register range Optional properties: - interrupts: Specify the INTC interrupt number Example: watchdog@120 { compatible = "ralink,rt2880-wdt"; reg = <0x120 0x10>; interrupt-parent = <&intc>; interrupts = <1>; }; |