Documentation / devicetree / bindings / iio / imu / adi,adis16480.yaml


Based on kernel version 6.8. Page generated on 2024-03-11 21:26 EST.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131
# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/iio/imu/adi,adis16480.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#

title: Analog Devices ADIS16480 and similar IMUs

maintainers:
  - Alexandru Tachici <alexandru.tachici@analog.com>

properties:
  compatible:
    enum:
      - adi,adis16375
      - adi,adis16480
      - adi,adis16485
      - adi,adis16488
      - adi,adis16490
      - adi,adis16495-1
      - adi,adis16495-2
      - adi,adis16495-3
      - adi,adis16497-1
      - adi,adis16497-2
      - adi,adis16497-3

  reg:
    maxItems: 1

  interrupts:
    minItems: 1
    maxItems: 2
    description: |
      Accepted interrupt types are:
      * IRQ_TYPE_EDGE_RISING
      * IRQ_TYPE_EDGE_FALLING

  interrupt-names:
    minItems: 1
    maxItems: 2
    description:
      Default if not supplied is DIO1.
    items:
      enum:
        - DIO1
        - DIO2
        - DIO3
        - DIO4

  spi-cpha: true
  spi-cpol: true

  reset-gpios:
    maxItems: 1
    description: Connected to RESET pin which is active low.

  clocks:
    maxItems: 1
    description: If not provided, then the internal clock is used.

  clock-names:
    description: |
      sync: In sync mode, the internal clock is disabled and the frequency
            of the external clock signal establishes therate of data
            collection and processing. See Fig 14 and 15 in the datasheet.
            The clock-frequency must be:
            * 3000 to 4500 Hz for adis1649x devices.
            * 700 to 2400 Hz for adis1648x devices.
      pps:  In Pulse Per Second (PPS) Mode, the rate of data collection and
            production is equal to the product of the external clock
            frequency and the scale factor in the SYNC_SCALE register, see
            Table 154 in the datasheet.
            The clock-frequency must be:
            * 1 to 128 Hz for adis1649x devices.
            * This mode is not supported by adis1648x devices.
    enum:
      - sync
      - pps

  adi,ext-clk-pin:
    $ref: /schemas/types.yaml#/definitions/string
    description: |
      The DIOx line to be used as an external clock input.
      Each DIOx pin supports only one function at a time (data ready line
      selection or external clock input). When a single pin has two
      two assignments, the enable bit for the lower priority function
      automatically resets to zero (disabling the lower priority function).
      Data ready has highest priority.
      If not provided then DIO2 is assigned as default external clock
      input pin.
    enum:
      - DIO1
      - DIO2
      - DIO3
      - DIO4

required:
  - compatible
  - reg
  - interrupts
  - spi-cpha
  - spi-cpol
  - spi-max-frequency

allOf:
  - $ref: /schemas/spi/spi-peripheral-props.yaml#

unevaluatedProperties: false

examples:
  - |
    #include <dt-bindings/interrupt-controller/irq.h>
    spi {
        #address-cells = <1>;
        #size-cells = <0>;
 
        imu@0 {
            compatible = "adi,adis16495-1";
            reg = <0>;
            spi-max-frequency = <3200000>;
            spi-cpol;
            spi-cpha;
            interrupts = <25 IRQ_TYPE_EDGE_FALLING>;
            interrupt-parent = <&gpio>;
            interrupt-names = "DIO2";
            clocks = <&adis16495_sync>;
            clock-names = "sync";
            adi,ext-clk-pin = "DIO1";
        };
    };
...