Documentation / devicetree / bindings / thermal / nvidia,tegra124-soctherm.yaml


Based on kernel version 6.8. Page generated on 2024-03-11 21:26 EST.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/thermal/nvidia,tegra124-soctherm.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#

title: NVIDIA Tegra124 SOCTHERM Thermal Management System

maintainers:
  - Thierry Reding <thierry.reding@gmail.com>
  - Jon Hunter <jonathanh@nvidia.com>

description: The SOCTHERM IP block contains thermal sensors, support for
  polled or interrupt-based thermal monitoring, CPU and GPU throttling based
  on temperature trip points, and handling external overcurrent notifications.
  It is also used to manage emergency shutdown in an overheating situation.

properties:
  compatible:
    enum:
      - nvidia,tegra124-soctherm
      - nvidia,tegra132-soctherm
      - nvidia,tegra210-soctherm

  reg:
    maxItems: 2

  reg-names:
    maxItems: 2

  interrupts:
    items:
      - description: module interrupt
      - description: EDP interrupt

  interrupt-names:
    items:
      - const: thermal
      - const: edp

  clocks:
    items:
      - description: thermal sensor clock
      - description: module clock

  clock-names:
    items:
      - const: tsensor
      - const: soctherm

  resets:
    items:
      - description: module reset

  reset-names:
    items:
      - const: soctherm
 
  "#thermal-sensor-cells":
    const: 1

  throttle-cfgs:
    $ref: thermal-cooling-devices.yaml
    description: A sub-node which is a container of configuration for each
      hardware throttle events. These events can be set as cooling devices.
      Throttle event sub-nodes must be named as "light" or "heavy".
    unevaluatedProperties: false
    patternProperties:
      "^(light|heavy|oc1)$":
        type: object
        additionalProperties: false

        properties:
          "#cooling-cells":
            const: 2

          nvidia,priority:
            $ref: /schemas/types.yaml#/definitions/uint32
            minimum: 1
            maximum: 100
            description: Each throttles has its own throttle settings, so the
              SW need to set priorities for various throttle, the HW arbiter
              can select the final throttle settings. Bigger value indicates
              higher priority, In general, higher priority translates to lower
              target frequency. SW needs to ensure that critical thermal
              alarms are given higher priority, and ensure that there is no
              race if priority of two vectors is set to the same value.

          nvidia,cpu-throt-percent:
            description: This property is for Tegra124 and Tegra210. It is the
              throttling depth of pulse skippers, it's the percentage
              throttling.
            minimum: 0
            maximum: 100

          nvidia,cpu-throt-level:
            $ref: /schemas/types.yaml#/definitions/uint32
            description: This property is only for Tegra132, it is the level
              of pulse skippers, which used to throttle clock frequencies. It
              indicates cpu clock throttling depth, and the depth can be
              programmed.
            enum:
              # none (TEGRA_SOCTHERM_THROT_LEVEL_NONE)
              - 0
              # low (TEGRA_SOCTHERM_THROT_LEVEL_LOW)
              - 1
              # medium (TEGRA_SOCTHERM_THROT_LEVEL_MED)
              - 2
              # high (TEGRA_SOCTHERM_THROT_LEVEL_HIGH)
              - 3

          nvidia,gpu-throt-level:
            $ref: /schemas/types.yaml#/definitions/uint32
            description: This property is for Tegra124 and Tegra210. It is the
              level of pulse skippers, which used to throttle clock
              frequencies. It indicates gpu clock throttling depth and can be
              programmed to any of the following values which represent a
              throttling percentage.
            enum:
              # none (0%, TEGRA_SOCTHERM_THROT_LEVEL_NONE)
              - 0
              # low (50%, TEGRA_SOCTHERM_THROT_LEVEL_LOW)
              - 1
              # medium (75%, TEGRA_SOCTHERM_THROT_LEVEL_MED)
              - 2
              # high (85%, TEGRA_SOCTHERM_THROT_LEVEL_HIGH)
              - 3
 
          # optional
          # Tegra210 specific and valid only for OCx throttle events
          nvidia,count-threshold:
            $ref: /schemas/types.yaml#/definitions/uint32
            description: Specifies the number of OC events that are required
              for triggering an interrupt. Interrupts are not triggered if the
              property is missing. A value of 0 will interrupt on every OC
              alarm.

          nvidia,polarity-active-low:
            $ref: /schemas/types.yaml#/definitions/flag
            description: Configures the polarity of the OC alaram signal. If
              present, this means assert low, otherwise assert high.

          nvidia,alarm-filter:
            $ref: /schemas/types.yaml#/definitions/uint32
            description: Number of clocks to filter event. When the filter
              expires (which means the OC event has not occurred for a long
              time), the counter is cleared and filter is rearmed.
            default: 0

          nvidia,throttle-period-us:
            description: Specifies the number of microseconds for which
              throttling is engaged after the OC event is deasserted.
            default: 0
 
  # optional
  nvidia,thermtrips:
    $ref: /schemas/types.yaml#/definitions/uint32-matrix
    description: |
      When present, this property specifies the temperature at which the
      SOCTHERM hardware will assert the thermal trigger signal to the Power
      Management IC, which can be configured to reset or shutdown the device.
      It is an array of pairs where each pair represents a tsensor ID followed
      by a temperature in milli Celcius. In the absence of this property the
      critical trip point will be used for thermtrip temperature.
 
      Note:
      - the "critical" type trip points will be used to set the temperature at
        which the SOCTHERM hardware will assert a thermal trigger if the
        "nvidia,thermtrips" property is missing.  When the thermtrips property
        is present, the breach of a critical trip point is reported back to
        the thermal framework to implement software shutdown.
 
      - the "hot" type trip points will be set to SOCTHERM hardware as the
        throttle temperature.  Once the temperature of this thermal zone is
        higher than it, it will trigger the HW throttle event.
    items:
      items:
        - description: sensor ID
          oneOf:
            - description: CPU sensor
              const: 0
            - description: MEM sensor
              const: 1
            - description: GPU sensor
              const: 2
            - description: PLLX sensor
              const: 3
        - description: temperature threshold (in millidegree Celsius)

required:
  - compatible
  - reg
  - reg-names
  - interrupts
  - interrupt-names
  - clocks
  - clock-names
  - resets
  - reset-names
  - "#thermal-sensor-cells"

allOf:
  - $ref: thermal-sensor.yaml
  - if:
      properties:
        compatible:
          contains:
            enum:
              - nvidia,tegra124-soctherm
              - nvidia,tegra210-soctherm
    then:
      properties:
        reg:
          items:
            - description: SOCTHERM register set
            - description: clock and reset controller registers

        reg-names:
          items:
            - const: soctherm-reg
            - const: car-reg

    else:
      properties:
        reg:
          items:
            - description: SOCTHERM register set
            - description: CCROC registers

        reg-names:
          items:
            - const: soctherm-reg
            - const: ccroc-reg

additionalProperties: false

examples:
  - |
    #include <dt-bindings/clock/tegra124-car.h>
    #include <dt-bindings/interrupt-controller/arm-gic.h>
    #include <dt-bindings/thermal/tegra124-soctherm.h>
 
    soctherm@700e2000 {
        compatible = "nvidia,tegra124-soctherm";
        reg = <0x700e2000 0x600>, /* SOC_THERM reg_base */
              <0x60006000 0x400>; /* CAR reg_base */
        reg-names = "soctherm-reg", "car-reg";
        interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>,
                     <GIC_SPI 51 IRQ_TYPE_LEVEL_HIGH>;
        interrupt-names = "thermal", "edp";
        clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
                 <&tegra_car TEGRA124_CLK_SOC_THERM>;
        clock-names = "tsensor", "soctherm";
        resets = <&tegra_car 78>;
        reset-names = "soctherm";
 
        #thermal-sensor-cells = <1>;
 
        nvidia,thermtrips = <TEGRA124_SOCTHERM_SENSOR_CPU 102500>,
                            <TEGRA124_SOCTHERM_SENSOR_GPU 103000>;
 
        throttle-cfgs {
            /*
             * When the "heavy" cooling device triggered,
             * the HW will skip cpu clock's pulse in 85% depth,
             * skip gpu clock's pulse in 85% level
             */
            heavy {
                nvidia,priority = <100>;
                nvidia,cpu-throt-percent = <85>;
                nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
 
                #cooling-cells = <2>;
            };
 
            /*
             * When the "light" cooling device triggered,
             * the HW will skip cpu clock's pulse in 50% depth,
             * skip gpu clock's pulse in 50% level
             */
            light {
                nvidia,priority = <80>;
                nvidia,cpu-throt-percent = <50>;
                nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_LOW>;
 
                #cooling-cells = <2>;
            };
 
            /*
             * If these two devices are triggered in same time, the HW throttle
             * arbiter will select the highest priority as the final throttle
             * settings to skip cpu pulse.
             */
 
            oc1 {
                nvidia,priority = <50>;
                nvidia,polarity-active-low;
                nvidia,count-threshold = <100>;
                nvidia,alarm-filter = <5100000>;
                nvidia,throttle-period-us = <0>;
                nvidia,cpu-throt-percent = <75>;
                nvidia,gpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
            };
        };
    };

  # referring to Tegra132's "reg", "reg-names" and "throttle-cfgs"
  - |
    thermal-sensor@700e2000 {
        compatible = "nvidia,tegra132-soctherm";
        reg = <0x700e2000 0x600>, /* SOC_THERM reg_base */
              <0x70040000 0x200>; /* CCROC reg_base */
        reg-names = "soctherm-reg", "ccroc-reg";
        interrupts = <GIC_SPI 48 IRQ_TYPE_LEVEL_HIGH>,
                     <GIC_SPI 51 IRQ_TYPE_LEVEL_HIGH>;
        interrupt-names = "thermal", "edp";
        clocks = <&tegra_car TEGRA124_CLK_TSENSOR>,
                 <&tegra_car TEGRA124_CLK_SOC_THERM>;
        clock-names = "tsensor", "soctherm";
        resets = <&tegra_car 78>;
        reset-names = "soctherm";
        #thermal-sensor-cells = <1>;
 
        throttle-cfgs {
            /*
             * When the "heavy" cooling device triggered,
             * the HW will skip cpu clock's pulse in HIGH level
             */
            heavy {
                nvidia,priority = <100>;
                nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_HIGH>;
 
                #cooling-cells = <2>;
            };
 
            /*
             * When the "light" cooling device triggered,
             * the HW will skip cpu clock's pulse in MED level
             */
            light {
                nvidia,priority = <80>;
                nvidia,cpu-throt-level = <TEGRA_SOCTHERM_THROT_LEVEL_MED>;
 
                #cooling-cells = <2>;
            };
 
            /*
             * If these two devices are triggered in same time, the HW throttle
             * arbiter will select the highest priority as the final throttle
             * settings to skip cpu pulse.
             */
        };
    };

  # referring to thermal sensors
  - |
    thermal-zones {
        cpu-thermal {
            polling-delay-passive = <1000>;
            polling-delay = <1000>;
 
            thermal-sensors = <&soctherm TEGRA124_SOCTHERM_SENSOR_CPU>;
 
            trips {
                cpu_shutdown_trip: shutdown-trip {
                    temperature = <102500>;
                    hysteresis = <1000>;
                    type = "critical";
                };
 
                cpu_throttle_trip: throttle-trip {
                    temperature = <100000>;
                    hysteresis = <1000>;
                    type = "hot";
                };
            };
 
            cooling-maps {
                map0 {
                    trip = <&cpu_throttle_trip>;
                    cooling-device = <&throttle_heavy 1 1>;
                };
            };
        };
    };